Soft-db Zen-Ten User guide Manual de usuario Pagina 16

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 35
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 15
User manual for the ZEN 3-channel X-LMS controller Soft dB inc.
3.2 Description of the control algorithm for the coupled case
Figure 9 shows a schematic of the coupled version of the controller. Unlike Figure 5
which shows the uncoupled version, the secondary cross-paths CxEy (xy) are now
included. This implies three optimizations for each channel using all error signals. This
algorithm requires three times the computation time of the uncoupled version.
Figure 9: Schematic for the coupled version of the control algorithm
The X-LMS optimization for a specific channel is computed in three steps with these
equations:
11
,
EOutCEMuWxWx xnormxn
n
+=
22
,,,
EOutCEMuWxWx xnormx
nn
+=
33
,,
1 EOutCEMuWxWx xnormx
n
n +=+
Where OutCxEy is the output of the secondary control path filter CxEy.
ZEN User Manual p. 16
Vista de pagina 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 34 35

Comentarios a estos manuales

Sin comentarios