Soft-db Opus Suite SLM 4-Ch Module Manual de usuario

Busca en linea o descarga Manual de usuario para Audio Soft-db Opus Suite SLM 4-Ch Module. Soft dB Opus Suite SLM 4-Ch Module User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 70
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Opus Suite
SLM 4-Ch Module
User Guide – v2.5
2012-12-06
Alto 6-Channel
Concerto 4-Channel
I-Track 6-Channel
Compatible Hardware:
Soft dB Inc.
1040,
Belvedere Avenue, Suite 215
Quebec (Quebec) Canada G1S 3G3
Toll free: 1
-866-686-0993 (USA and Canada)
E-mail: contact@softdb.com
Vista de pagina 0
1 2 3 4 5 6 ... 69 70

Indice de contenidos

Pagina 1 - Opus Suite

Opus Suite SLM 4-Ch Module User Guide – v2.5 2012-12-06 Alto 6-Channel Concerto 4-Channel I-Track 6-Channel Compatible Hardware: Soft dB Inc. 1040,

Pagina 2 - CONTENTS

7 5 Main Interface The main interface is divided in five areas: 1) Measure controls (see section 5.1, p. 8) 2) File Info (see section 5.2, p. 9)

Pagina 3

8 Input Setup Number of inputs(1 to 4) Input type (ICP or AC) Dynamic range Sensor sensitivity Display Setup Elements to display during the measureme

Pagina 4 - 1 Introduction

9 5.2 File Info File Info This indicator displays the actual DataSet ID. These two buttons are used to open the previous/next DataSets in the Reco

Pagina 5 - 2 Compatible Hardware

10 Red background: Audio recording in progress on this input. Over/Under Range Transparent background: Input level is between the dynamic range limi

Pagina 6 - 3 Opus Environment

11 Launches the Record Setup (see section 8 ,p. 31) Comment / Tag Button Allows the user to write a comment on the measurement before it starts. Wh

Pagina 7

12 5.5.2 Y Axis Scaling Each graph has a icon at the bottom left corner. Clicking on this icon adjusts the Y scale to the graph data. 5.5.3 Cur

Pagina 8

13 5.5.3.1 Complementary Actions Associated to the Cursors 1) The length of the Historic graph is limited to 1000 values. When the number of val

Pagina 9

14 3) Selecting versus on a Spectrum graph displays either the Global value or the Band value (associated to the cursor) on the Legend. 5.5.

Pagina 10 - 5 Main Interface

15 5.5.4.1 Selecting the record The Audio Recording Indicator is displayed on the top of the magnified Time History graph. In the case of simultane

Pagina 11 - 5.1 Measure Controls

16 5.5.4.2 Playing the record Click the button at the right end of the Audio Recording Indicator to start playing the record. Adjust the volume

Pagina 12 - 5.3 Measure Info

i CONTENTS 1 Introduction ...

Pagina 13 - 5.4 Menu Bar

17 6 Input Setup Click the button on the main interface to launch the Input Setup interface. The Input Setup allows defining: • Input Selection

Pagina 14 - 5.5 Display Area

18 6.1 Input Selection The Concerto allows the user to perform measurements on 1 to 4 inputs simultaneously. Click on the / button to enable or

Pagina 15 - 5.5.3 Cursors

19 6.4 Input Sensitivity and Calibration The input sensitivity can be manually changed in the text field or it can be calibrated using the calibrati

Pagina 16

20 6.5 Reference Value The reference value is the unit reference from which the decibel (dB) is calculated. 6.6 FFT High Pass Filter The FFT spectr

Pagina 17

21 7 Display Setup During a measurement, all acoustical parameters are calculated and available for display. The button launches the Display Setup

Pagina 18

22 7.2 Graph Type For each graph, the Graph Type list box allows the user to select the graph type. ← Time History Graph of global levels (see sect

Pagina 19

23 7.2.1 Time History Graph Available data Data Type Measure Type Display Type Freq Weighting Global level SPL Slow Instant, Max or Min A, C or Z

Pagina 20 - 6 Input Setup

24 7.2.2 1/3 Octave Spectrum Graph Available data Data Type Measure Type Display Type Freq Weighting 1/3 Octave Spectrum level SPL Slow Instant, M

Pagina 21 - 6.3 Dynamic Range

25 7.2.3 FFT Spectrum Graph Available data Data Type Measure Type Display Type Freq Weighting FFT Spectrum level Leq Running Average A, C or Z SEL

Pagina 22 - 6.4.1 Calibration Interface

26 7.2.4 Numeric Indicators Available data Data Type Measure Type Display Type Freq Weighting Global level SPL Slow Instant, Max or Min A, C or Z

Pagina 23 - 6.6 FFT High Pass Filter

ii 7.2.6 Camera display ... 28 7.3 Dat

Pagina 24 - 7 Display Setup

27 7.2.5 Statistic Graph Available data Data Type Measure Type Display Type Freq Weighting Global level SPL Slow Max, Min and Statistics A, C or Z

Pagina 25 - 7.2 Graph Type

28 7.2.6 Camera display The camera display can be used to display the life video captured by a webcam. The camera settings can be adjusted from th

Pagina 26 - 7.2.1 Time History Graph

29 7.3 Data Selection The Edit button of the Data Selection allows selecting the data to display on each graph. Display Element Click / to ena

Pagina 27

30 7.4 X Axis Properties The X axis range is automatically adjusted to the contained data. However, the 1/3 octave spectrum and FFT spectrum graphs

Pagina 28 - 7.2.3 FFT Spectrum Graph

31 8 Record Setup The Record Setup allows the user to define: • Record Destination (see section 8.1, p. 32) • Dataset ID (see section 8.2, p. 37)

Pagina 29 - 7.2.4 Numeric Indicators

32 8.1 Record Destination Obviously, the measurements can be saved on the local drive. These data are recorded in a format compatible for post-proce

Pagina 30 - 7.2.5 Statistic Graph

33 These DataSets are displayed as on the explorer window. The File/Open function in the main interface opens these DataSets to display them

Pagina 31 - 7.2.6 Camera display

34 8.1.2 Record on the Web When Web + Local Drive is selected, the data are saved both locally (see above) and remotely. New controls appear on the

Pagina 32 - 7.3 Data Selection

35 The combination of the Base Path, Unit Serial Number and Station Name form the record path on the FTP server. The Unit Serial Number is related t

Pagina 33 - 7.5 Y Axis Range

36 For example: • 20120831_14h56m15_Per1_DS0.dat: DataSet started on 2012-08-31 at 14:46:15, averaging period 1 (the main one), the first DataSet of

Pagina 34 - 8 Record Setup

1 1 Introduction Congratulations on your purchase of the Opus Suite SLM 4-ch module. The Opus Software Suite is a Sound and Vibration software that

Pagina 35 - 8.1 Record Destination

37 8.2 Dataset ID DataSet ID The ID Format allows the user to choose the name format of dataset files to be recorded. • Four-digit increment of t

Pagina 36

38 8.2.1 DataSet and Leq Alignment In several cases, it is useful to align the Leq measurements to match the time on the clock. For example, it may

Pagina 37 - 8.1.2 Record on the Web

39 8.3 Auto-Store Setup The Auto-Store Setup provides several options for saving measurements. AutoStore Modes The measurement will stop after the

Pagina 38

40 8.4 Data Selection The Data Selection area of the Record Setup Interface displays a summary of the options selected by the user. It also display

Pagina 39

41 8.4.1.1 Instantaneous Record Mode The Instantaneous Record Mode records instantaneous values at a rate defined by the Instant Rate. This record m

Pagina 40 - 8.2 Dataset ID

42 Global SPL Slow Statistics A, C or Z SPL Fast SPL Impulse SPL Peak Leq and SEL Average 1/3 Octave Spectrum SPL Slow Statistics A, C and Z SPL Fast

Pagina 41 - 8.2.2 DataSet File Size

43 8.4.2.2 Average Record Mode In Average Record Mode, the record rate can be set between 1 s to 24 hrs. Simply click on the field to modify this v

Pagina 42 - 8.3 Auto-Store Setup

44 The Statistic L% Selection control let the user decide what statistics data will be saved. This control applies to all statistic data (both globa

Pagina 43 - 8.4 Data Selection

45 8.5 Audio Setup The audio recordings are useful to identify the source of the noise that was measured. Recordings can be done on a level trigge

Pagina 44

46 common audio players. Applying a gain exposes the audio signal to numerical saturations. Trig Tab The file format of the audio recordings. • OF

Pagina 45 - 8.4.2 Sampling Rate

2 2 Compatible Hardware Every hardware option has an embedded state of the art Soft dB SR-MK3 DSP board allowing real-time and precise measurement w

Pagina 46 - 8.4.3 Data Selections

47 OFF No audio recording is performed. ON Continuous audio recording is performed from the start to the end of a measurement. On Trig Recording is t

Pagina 47

48 8.6 Photo Setup Along with the audio recordings, photos can be taken as an event occur or periodically. If activated, a camera will record a ph

Pagina 48 - 8.5 Audio Setup

49 8.6.2 Camera Setup Interface The Camera Setup interface is available from the Photo Setup interface. Camera Setup Interface The Camera Preview

Pagina 49

50 8.7 Generator Setup To edit the Generator Setup, press the corresponding button on the Record Setup interface. There are two independent generat

Pagina 50

51 8.7.1 Calibration Check The calibration check is generally used in long term or permanent environmental system. It is intended to periodically ve

Pagina 51 - 8.6 Photo Setup

52 Averaging Controls Starts and stops the average of the averaging of the spectrum. Once the Average Time in completed, the user is asked if the c

Pagina 52

53 9 Data Exporter The Data Exporter utility is used to export data contained in a dataset in a .txt or .xls file Directory Path Shortcuts Tra

Pagina 53 - 8.7 Generator Setup

54 Directory Path Displays the path of the active directory. File/Folder Operators Can be used to: • Go to parent directory • Open directory • Ren

Pagina 54 - 8.7.1 Calibration Check

55 10 Explorer Dialog Explorer Window Controls and Indicators File/Folder Operators • Go to parent directory • Open directory • Create new folde

Pagina 55

56 11 File Manager The File manager is used to perform most file operations: • Navigate the directory structure • Create folders • Rename files a

Pagina 56 - 9 Data Exporter

3 3 Opus Environment The Concerto unit comes equipped with the Opus Environment. This environment acts as a main interface that gives access to t

Pagina 57

57 Directory Path Displays the path of the active directory. Shortcuts Allows easy access to common directories. When the File Manager is used on a s

Pagina 58 - 10 Explorer Dialog

58 Appendix 1: Concerto Hardware Connections 4 Inputs Mic Stand DC in ¼ 20 insert Power-on button Second Battery 2 Outputs USB port Right click

Pagina 59 - 11 File Manager

59 Power on/off Turn On Press the trigger button located at the back of the unit This key has two (2) functions: 1. To turn the unit ON. 2. Start

Pagina 60

60 Power Reset If the Concerto happens to crash and it is not possible to take back the control, a power reset might be necessary. To complete the po

Pagina 61

61 Inputs and Signal Processing Specifications (Embedded Signal Ranger MK3 DSP Board) DSP Processor Texas Instruments TMS320C6424 Inputs 4 Outputs 2

Pagina 62

62 Appendix 2: 1/3 Octave Filters – IEC 61260 Class 1/ANSI S1.11 1/3 Octave Filters The 1/3 octave filters are computed at low-level in real time (at

Pagina 63

63 Shape Test Numerical Results at 1 kHz The following table presents the numerical results of the shape test at 1 kHz: Frequency (Hz) Low limit (dB)

Pagina 64

64 1/3 Octave Filter Linearity The linearity of the 1/3-octave filter has been measured for both ranges (low and high). The experimentation is done w

Pagina 65 - Attenuation dB

65 Frequency (Hz) Saturation Level (dB) Minimum Linear Level (dB) Linear Dynamic Range (dB) Noise Floor (dB) 10000 120.5 26.3 94.2 16.9 12500 120.5

Pagina 66

66 Frequency (Hz) Saturation Level (dB) Minimum Linear Level (dB) Linear Dynamic Range (dB) Noise Floor (dB) 8000 132.5 32.7 99.8 22.4 10000 132.5

Pagina 67

4 The Clock indicator displays the time and date on the unit. To change time, simply click on the indicator to display a dialog window. The Quit bu

Pagina 68

67 Summation Test (High Range Case)-0.5-0.4-0.3-0.2-0.100.10.20.30.40.510 1001000 10000 100000Frequency (Hz)Amplitude dB

Pagina 69 - Amplitude dB

5 4 Quick Start The AutoStore Setup is presumed to set to OFF. Step 1 Set the Averaging Time Click on the field to change the Leq Averaging Time.

Pagina 70

6 Before Measurement During Measurement After Measurement ← Run / Pause / Continue Button ← Stop / Save Button ← Current DataSet ← Previous / N

Comentarios a estos manuales

Sin comentarios