Soft-db Opus Suite Data Logger Module Manual de usuario Pagina 46

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 62
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 45
45
The parameters are described in the following table:
Integration Parameters
Description
A simple or double operation can be done. A first (simple integration)
or second order (double integration) filter is used following this
parameter.
This is the cut-off frequency for the filter used in the integration
process. We suggest using an Fcut(Hz) parameter that fits with the
sensor used. A typical accelerometer sensor has a flat frequency
response that starts at around 20 Hz.
This control allows selecting the group of channels for which the integration will be done.
This button launches the integration operation.
Vista de pagina 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 61 62

Comentarios a estos manuales

Sin comentarios